›› 2010, Vol. 41 ›› Issue (1): 153-156.doi: 10.3969/j.issn.0529-1356.2010.01.030

• 论著 • 上一篇    下一篇

经喙突肩胛骨关节盂螺钉内固定的最优化计算机辅助测量

陈亿民1;洪俊毅1;毕大卫1;马海涛1;廖胜辉2* ;王辉1;祖罡1   

  1. 1.杭州市萧山区第一人民医院骨科, 杭州311200; 2.浙江大学计算机学院CAD&CG国家重点实验室,杭州310027
  • 收稿日期:2009-02-15 修回日期:2009-05-07 出版日期:2010-02-06
  • 通讯作者: 廖胜辉

Optimal computer aided measure for screw internal fixation in the cavitas glenoidalis through human coracoid process of scapula

  1. 1. Department of Orthopaedics,the First People’s Hospital of Xiaoshan, Hangzhou311200, China; 2. State Key Laboratory of CAD and CG, Zhejiang University, Hangzhou310027, China
  • Received:2009-02-15 Revised:2009-05-07 Online:2010-02-06
  • Contact: LIAO Sheng-hui

关键词: 肩胛骨, 关节盂, 喙突, 螺钉内固定, 计算机辅助测量, 最优化方法,

Abstract: Objective To investigate a special optimization technique for computer aided measure, and provide anatomical basis for screw internal fixation in the cavitas glenoidalis through the coracoid process of scapula. Methods Thirty accurate scapula models were reconstructed from CT data sets. First, special optimization objective function was designed for single screw internal fixation configuration, and the optimal placement of screw was found automatically under constraints. Then, the placements of double screws internal fixation configuration were searched taking advantage of principal component analysis. Finally, statistical measure data were provided according to new anatomical reference landmarks for clinical use. Results For single screw internal fixation configuration, the distance from the optimal screw entry point P to the acromion process point X was (39.15±2.28) mm, to the coracoid process point Y was (28.66±2.68) mm, to the angulus superior point Z was (61.13±6.57) mm; The angle was (81.27±7.15)° between PX and PY, and (133.27±6.84)° between PX and PZ. The mean inclination of the lag screw was (104.08±4.41)° for the angle with line PX, (101.29±3.51)° with line PY, and (76.23±5.03)° with line PZ. For double screws configuration, the distance from the original single screw entry point P to the screw entry point E was (5.12±1.37)mm,to the screw entry point F was (3.88±0.94)mm. The angle between the long axis of coracoid process and li

Key words: Scapula, Cavitas glenoidalis, Coracoid process, Screw internal fixation, Computer aided measure, Optimization technique, Human

中图分类号: